xref: /netbsd-src/sys/arch/macppc/dev/smartbat.c (revision d8ca82601f62521c5c8933d82e784e2634ff03d0)
1 /*	$NetBSD: smartbat.c,v 1.14 2012/11/01 15:54:28 macallan Exp $ */
2 
3 /*-
4  * Copyright (c) 2007 Michael Lorenz
5  *               2008 Magnus Henoch
6  * All rights reserved.
7  *
8  * Redistribution and use in source and binary forms, with or without
9  * modification, are permitted provided that the following conditions
10  * are met:
11  * 1. Redistributions of source code must retain the above copyright
12  *    notice, this list of conditions and the following disclaimer.
13  * 2. Redistributions in binary form must reproduce the above copyright
14  *    notice, this list of conditions and the following disclaimer in the
15  *    documentation and/or other materials provided with the distribution.
16  *
17  * THIS SOFTWARE IS PROVIDED BY THE NETBSD FOUNDATION, INC. AND CONTRIBUTORS
18  * ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED
19  * TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
20  * PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE FOUNDATION OR CONTRIBUTORS
21  * BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
22  * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
23  * SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
24  * INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
25  * CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
26  * ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
27  * POSSIBILITY OF SUCH DAMAGE.
28  */
29 
30 #include <sys/cdefs.h>
31 __KERNEL_RCSID(0, "$NetBSD: smartbat.c,v 1.14 2012/11/01 15:54:28 macallan Exp $");
32 
33 #include <sys/param.h>
34 #include <sys/systm.h>
35 #include <sys/kernel.h>
36 #include <sys/device.h>
37 #include <sys/proc.h>
38 
39 #include <dev/sysmon/sysmonvar.h>
40 #include <dev/sysmon/sysmon_taskq.h>
41 
42 #include <macppc/dev/pmuvar.h>
43 #include <macppc/dev/batteryvar.h>
44 #include <sys/bus.h>
45 #include "opt_battery.h"
46 
47 #ifdef SMARTBAT_DEBUG
48 #define DPRINTF printf
49 #define static /* static */
50 #else
51 #define DPRINTF while (0) printf
52 #endif
53 
54 #define BAT_AC_PRESENT		0
55 
56 #define BAT_PRESENT		0
57 #define BAT_VOLTAGE		1
58 #define BAT_CURRENT		2
59 #define BAT_MAX_CHARGE		3
60 #define BAT_CHARGE		4
61 #define BAT_CHARGING		5
62 #define BAT_CHARGE_STATE	6
63 #define BAT_FULL		7
64 #define BAT_NSENSORS		8  /* number of sensors */
65 
66 struct smartbat_softc {
67 	device_t sc_dev;
68 	struct pmu_ops *sc_pmu_ops;
69 	int sc_num;
70 
71 	/* envsys stuff */
72 	struct sysmon_envsys *sc_bat_sme;
73 	envsys_data_t sc_bat_sensor[BAT_NSENSORS];
74 	struct sysmon_envsys *sc_ac_sme;
75 	envsys_data_t sc_ac_sensor[1];
76 	struct sysmon_pswitch sc_sm_acpower;
77 	int sc_have_ac;
78 
79 	/* battery status */
80 	int sc_flags;
81 	int sc_oflags;
82 	int sc_voltage;
83 	int sc_charge;
84 	int sc_max_charge;
85 	int sc_warn;
86 	int sc_low;
87 	int sc_draw;
88 	int sc_time;
89 	uint32_t sc_timestamp;
90 };
91 
92 static void smartbat_attach(device_t, device_t, void *);
93 static int smartbat_match(device_t, cfdata_t, void *);
94 static void smartbat_setup_envsys(struct smartbat_softc *);
95 static void smartbat_refresh(struct sysmon_envsys *, envsys_data_t *);
96 static void smartbat_get_limits(struct sysmon_envsys *, envsys_data_t *,
97     sysmon_envsys_lim_t *, uint32_t *);
98 static void smartbat_refresh_ac(struct sysmon_envsys *, envsys_data_t *);
99 static void smartbat_poll(void *);
100 static int smartbat_update(struct smartbat_softc *, int);
101 
102 CFATTACH_DECL_NEW(smartbat, sizeof(struct smartbat_softc),
103     smartbat_match, smartbat_attach, NULL, NULL);
104 
105 static int
smartbat_match(device_t parent,cfdata_t cf,void * aux)106 smartbat_match(device_t parent, cfdata_t cf, void *aux)
107 {
108 	struct battery_attach_args *baa = aux;
109 
110 	if (baa->baa_type == BATTERY_TYPE_SMART)
111 		return 1;
112 
113 	return 0;
114 }
115 
116 static void
smartbat_attach(device_t parent,device_t self,void * aux)117 smartbat_attach(device_t parent, device_t self, void *aux)
118 {
119 	struct battery_attach_args *baa = aux;
120 	struct smartbat_softc *sc = device_private(self);
121 
122 	sc->sc_dev = self;
123 	sc->sc_pmu_ops = baa->baa_pmu_ops;
124 	sc->sc_num = baa->baa_num;
125 
126 	/*
127 	 * we can have more than one instance but only the first one needs
128 	 * to report AC status
129 	 */
130 	sc->sc_have_ac = FALSE;
131 	if (sc->sc_num == 0)
132 		sc->sc_have_ac = TRUE;
133 
134 	printf(" addr %d: smart battery\n", sc->sc_num);
135 
136 	sc->sc_charge = 0;
137 	sc->sc_max_charge = 0;
138 	smartbat_update(sc, 1);
139 	/* trigger a status update */
140 	sc->sc_oflags = ~sc->sc_flags;
141 
142 	smartbat_setup_envsys(sc);
143 
144 	if (sc->sc_have_ac) {
145 		memset(&sc->sc_sm_acpower, 0, sizeof(struct sysmon_pswitch));
146 		sc->sc_sm_acpower.smpsw_name = "AC Power";
147 		sc->sc_sm_acpower.smpsw_type = PSWITCH_TYPE_ACADAPTER;
148 		if (sysmon_pswitch_register(&sc->sc_sm_acpower) != 0)
149 			printf("%s: unable to register AC power status with " \
150 			       "sysmon\n",
151 			    device_xname(sc->sc_dev));
152 		sc->sc_pmu_ops->register_callback(sc->sc_pmu_ops->cookie,
153 		    smartbat_poll, sc);
154 	}
155 }
156 
157 
158 static void
smartbat_setup_envsys(struct smartbat_softc * sc)159 smartbat_setup_envsys(struct smartbat_softc *sc)
160 {
161 	int i;
162 
163 	if (sc->sc_have_ac) {
164 
165 #define INITDATA(index, unit, string)					\
166 	sc->sc_ac_sensor[index].units = unit;     			\
167 	sc->sc_ac_sensor[index].state = ENVSYS_SINVALID;		\
168 	snprintf(sc->sc_ac_sensor[index].desc,				\
169 	    sizeof(sc->sc_ac_sensor[index].desc), "%s", string);
170 
171 		INITDATA(BAT_AC_PRESENT, ENVSYS_INDICATOR, "connected");
172 #undef INITDATA
173 
174 		sc->sc_ac_sme = sysmon_envsys_create();
175 
176 		if (sysmon_envsys_sensor_attach(sc->sc_ac_sme,
177 					&sc->sc_ac_sensor[0])) {
178 			sysmon_envsys_destroy(sc->sc_ac_sme);
179 			return;
180 		}
181 
182 		sc->sc_ac_sme->sme_name = "AC Adaptor";
183 		sc->sc_ac_sme->sme_cookie = sc;
184 		sc->sc_ac_sme->sme_refresh = smartbat_refresh_ac;
185 		sc->sc_ac_sme->sme_class = SME_CLASS_ACADAPTER;
186 
187 		if (sysmon_envsys_register(sc->sc_ac_sme)) {
188 			aprint_error("%s: unable to register AC with sysmon\n",
189 			    device_xname(sc->sc_dev));
190 			sysmon_envsys_destroy(sc->sc_ac_sme);
191 		}
192 	}
193 
194 	sc->sc_bat_sme = sysmon_envsys_create();
195 
196 #define INITDATA(index, unit, string)					\
197 	sc->sc_bat_sensor[index].units = unit;     			\
198 	sc->sc_bat_sensor[index].state = ENVSYS_SINVALID;		\
199 	snprintf(sc->sc_bat_sensor[index].desc,				\
200 	    sizeof(sc->sc_bat_sensor[index].desc), "%s", string);
201 
202 	INITDATA(BAT_PRESENT, ENVSYS_INDICATOR, "Battery present");
203 	INITDATA(BAT_VOLTAGE, ENVSYS_SVOLTS_DC, "Battery voltage");
204 	INITDATA(BAT_CURRENT, ENVSYS_SAMPS, "Battery current");
205 	INITDATA(BAT_MAX_CHARGE, ENVSYS_SWATTHOUR, "Battery design cap");
206 	INITDATA(BAT_CHARGE, ENVSYS_SWATTHOUR, "Battery charge");
207 	INITDATA(BAT_CHARGING, ENVSYS_BATTERY_CHARGE, "Battery charging");
208 	INITDATA(BAT_CHARGE_STATE, ENVSYS_BATTERY_CAPACITY,
209 	    "Battery charge state");
210 	INITDATA(BAT_FULL, ENVSYS_INDICATOR, "Battery full");
211 #undef INITDATA
212 
213 	sc->sc_bat_sensor[BAT_CHARGE_STATE].value_cur =
214 	    ENVSYS_BATTERY_CAPACITY_NORMAL;
215 	sc->sc_bat_sensor[BAT_CHARGE_STATE].state = ENVSYS_SVALID;
216 	sc->sc_bat_sensor[BAT_CHARGING].value_cur = TRUE;
217 	sc->sc_bat_sensor[BAT_CHARGING].state = ENVSYS_SVALID;
218 	sc->sc_bat_sensor[BAT_CHARGING].value_cur = TRUE;
219 	sc->sc_bat_sensor[BAT_CHARGING].state = ENVSYS_SVALID;
220 
221 	for (i = 0; i < BAT_NSENSORS; i++)
222 		sc->sc_bat_sensor[i].flags = ENVSYS_FMONNOTSUPP;
223 
224 	sc->sc_bat_sensor[BAT_CHARGE].flags =
225 	    ENVSYS_FMONLIMITS | ENVSYS_FPERCENT | ENVSYS_FVALID_MAX;
226 	sc->sc_bat_sensor[BAT_CHARGE_STATE].flags = ENVSYS_FMONSTCHANGED;
227 
228 	for (i = 0; i < BAT_NSENSORS; i++) {
229 		if (sysmon_envsys_sensor_attach(sc->sc_bat_sme,
230 						&sc->sc_bat_sensor[i])) {
231 			sysmon_envsys_destroy(sc->sc_bat_sme);
232 			return;
233 		}
234 	}
235 
236 	sc->sc_low  = sc->sc_max_charge * 1000 / 100 * 10; /* 10% */
237 	sc->sc_warn = sc->sc_max_charge * 1000 / 100 * 20; /* 20% */
238 
239 
240 	sc->sc_bat_sme->sme_name = device_xname(sc->sc_dev);
241 	sc->sc_bat_sme->sme_cookie = sc;
242 	sc->sc_bat_sme->sme_refresh = smartbat_refresh;
243 	sc->sc_bat_sme->sme_class = SME_CLASS_BATTERY;
244 	sc->sc_bat_sme->sme_flags = SME_POLL_ONLY | SME_INIT_REFRESH;
245 	sc->sc_bat_sme->sme_get_limits = smartbat_get_limits;
246 
247 	if (sysmon_envsys_register(sc->sc_bat_sme)) {
248 		aprint_error("%s: unable to register with sysmon\n",
249 		    device_xname(sc->sc_dev));
250 		sysmon_envsys_destroy(sc->sc_bat_sme);
251 	}
252 }
253 
254 static void
smartbat_refresh(struct sysmon_envsys * sme,envsys_data_t * edata)255 smartbat_refresh(struct sysmon_envsys *sme, envsys_data_t *edata)
256 {
257 	struct smartbat_softc *sc = sme->sme_cookie;
258 	int which = edata->sensor, present, ch;
259 
260 	smartbat_update(sc, 0);
261 	present = (sc->sc_flags & PMU_PWR_BATT_PRESENT) != 0;
262 	ch = sc->sc_charge * 100 / sc->sc_max_charge;
263 
264 	if (present) {
265 		edata->state = ENVSYS_SVALID;
266 		switch (which) {
267 		case BAT_PRESENT:
268 			edata->value_cur = present;
269 			break;
270 		case BAT_VOLTAGE:
271 			edata->value_cur = sc->sc_voltage * 1000;
272 			break;
273 		case BAT_CURRENT:
274 			edata->value_cur = sc->sc_draw * 1000;
275 			break;
276 		case BAT_MAX_CHARGE:
277 			edata->value_cur = sc->sc_max_charge * 1000;
278 			break;
279 		case BAT_CHARGE:
280 			edata->value_cur = sc->sc_charge * 1000;
281 			edata->value_max = sc->sc_max_charge * 1000;
282 			if (ch < 6) {
283 				edata->state = ENVSYS_SCRITICAL;
284 			} else if (edata->value_cur < sc->sc_low) {
285 				edata->state = ENVSYS_SCRITUNDER;
286 			} else if (edata->value_cur < sc->sc_warn) {
287 				edata->state = ENVSYS_SWARNUNDER;
288 			}
289 			break;
290 		case BAT_CHARGING:
291 			if ((sc->sc_flags & PMU_PWR_BATT_CHARGING) &&
292 			    (sc->sc_flags & PMU_PWR_AC_PRESENT))
293 				edata->value_cur = 1;
294 			else
295 				edata->value_cur = 0;
296 			break;
297 		case BAT_CHARGE_STATE:
298 			{
299 				int chr = sc->sc_charge * 1000;
300 
301 				if (ch < 6) {
302 					edata->value_cur =
303 					    ENVSYS_BATTERY_CAPACITY_CRITICAL;
304 				} else if (chr < sc->sc_low) {
305 					edata->value_cur =
306 					    ENVSYS_BATTERY_CAPACITY_LOW;
307 				} else if (chr < sc->sc_warn) {
308 					edata->value_cur =
309 					    ENVSYS_BATTERY_CAPACITY_WARNING;
310 				} else {
311 					edata->value_cur =
312 					    ENVSYS_BATTERY_CAPACITY_NORMAL;
313 				}
314 			}
315 			break;
316 		case BAT_FULL:
317 			edata->value_cur = (sc->sc_flags & PMU_PWR_BATT_FULL);
318 			break;
319 		}
320 	} else {
321 		/* battery isn't there */
322 		switch (which) {
323 		case BAT_PRESENT:
324 			edata->value_cur = present;
325 			edata->state = ENVSYS_SVALID;
326 			break;
327 		case BAT_CHARGE_STATE:
328 			/*
329 			 * envsys crashes if this isn't a valid value even
330 			 * when the sensor itself is invalid
331 			 */
332 			edata->value_cur = ENVSYS_BATTERY_CAPACITY_NORMAL;
333 			edata->state = ENVSYS_SINVALID;
334 			break;
335 		default:
336 			edata->state = ENVSYS_SINVALID;
337 			edata->value_cur = 0;
338 		}
339 	}
340 }
341 
342 static void
smartbat_get_limits(struct sysmon_envsys * sme,envsys_data_t * edata,sysmon_envsys_lim_t * limits,uint32_t * props)343 smartbat_get_limits(struct sysmon_envsys *sme, envsys_data_t *edata,
344     sysmon_envsys_lim_t *limits, uint32_t *props)
345 {
346 	struct smartbat_softc *sc = sme->sme_cookie;
347 
348 	if (edata->sensor != BAT_CHARGE)
349 		return;
350 
351 	limits->sel_critmin = sc->sc_low;
352 	limits->sel_warnmin = sc->sc_warn;
353 
354 	*props |= PROP_BATTCAP | PROP_BATTWARN | PROP_DRIVER_LIMITS;
355 }
356 
357 static void
smartbat_refresh_ac(struct sysmon_envsys * sme,envsys_data_t * edata)358 smartbat_refresh_ac(struct sysmon_envsys *sme, envsys_data_t *edata)
359 {
360 	struct smartbat_softc *sc = sme->sme_cookie;
361 	int which = edata->sensor;
362 
363 	smartbat_update(sc, 0);
364 	switch (which) {
365 		case BAT_AC_PRESENT:
366 			edata->value_cur =
367 			    ((sc->sc_flags & PMU_PWR_AC_PRESENT) != 0);
368 			edata->state = ENVSYS_SVALID;
369 			break;
370 		default:
371 			edata->value_cur = 0;
372 			edata->state = ENVSYS_SINVALID;
373 	}
374 }
375 
376 /*
377  * Thanks to Paul Mackerras and Fabio Riccardi's Linux implementation
378  * for a clear description of the PMU results.
379  */
380 static int
smartbat_update(struct smartbat_softc * sc,int out)381 smartbat_update(struct smartbat_softc *sc, int out)
382 {
383 	int len;
384 	uint8_t buf[16];
385 	int8_t *sbuf = (int8_t *)buf;
386 	uint8_t battery_number;
387 
388 	if (sc->sc_timestamp == time_second)
389 		return 0;
390 	sc->sc_timestamp = time_second;
391 
392 	/* sc_num starts from 0, but we need to start from 1 */
393 	battery_number = sc->sc_num + 1;
394 	len = sc->sc_pmu_ops->do_command(sc->sc_pmu_ops->cookie,
395 					 PMU_SMART_BATTERY_STATE,
396 					 1, &battery_number,
397 					 16, buf);
398 
399 	if (len < 0) {
400 		DPRINTF("%s: couldn't get battery data\n",
401 		    device_xname(sc->sc_dev));
402 		/* XXX: the return value is never checked */
403 		return -1;
404 	}
405 
406 	/* Now, buf[0] is the command number, which we already know.
407 	   That's why all indexes are off by one compared to
408 	   pm_battery_info_smart in pm_direct.c.
409 	*/
410 	sc->sc_flags = buf[2];
411 
412         /* XXX: are these all valid for smart batteries? */
413 	if (out) {
414 		printf(" flags: %x", buf[2]);
415 		if (buf[2] & PMU_PWR_AC_PRESENT)
416 			printf(" AC");
417 		if (buf[2] & PMU_PWR_BATT_CHARGING)
418 			printf(" charging");
419 		if (buf[2] & PMU_PWR_BATT_PRESENT)
420 			printf(" present");
421 		if (buf[2] & PMU_PWR_BATT_FULL)
422 			printf(" full");
423 		printf("\n");
424 	}
425 
426 	switch(buf[1]) {
427 	case 3:
428 	case 4:
429 		sc->sc_charge = buf[3];
430 		sc->sc_max_charge = buf[4];
431 		sc->sc_draw = sbuf[5];
432 		sc->sc_voltage = buf[6];
433 		break;
434 	case 5:
435 		sc->sc_charge = ((buf[3] << 8) | (buf[4]));
436 		sc->sc_max_charge = ((buf[5] << 8) | (buf[6]));
437 		sc->sc_draw = sbuf[7];
438 		sc->sc_voltage = ((buf[9] << 8) | (buf[8]));
439 		break;
440 	default:
441 		/* XXX - Error condition */
442 		DPRINTF("%s: why is buf[1] %x?\n", device_xname(sc->sc_dev),
443 		   buf[1]);
444 		sc->sc_charge = 0;
445 		sc->sc_max_charge = 0;
446 		sc->sc_draw = 0;
447 		sc->sc_voltage = 0;
448 		break;
449 	}
450 
451 	return 1;
452 }
453 
454 static void
smartbat_poll(void * cookie)455 smartbat_poll(void *cookie)
456 {
457 	struct smartbat_softc *sc = cookie;
458 
459 	smartbat_update(sc, 0);
460 	if ((sc->sc_flags & PMU_PWR_AC_PRESENT) == sc->sc_oflags)
461 		return;
462 
463 	sc->sc_oflags = sc->sc_flags & PMU_PWR_AC_PRESENT;
464 	sc->sc_ac_sensor[0].value_cur = sc->sc_oflags ? 1 : 0;
465 	sysmon_pswitch_event(&sc->sc_sm_acpower,
466 	    sc->sc_oflags ? PSWITCH_EVENT_PRESSED :
467 	    PSWITCH_EVENT_RELEASED);
468 }
469