xref: /spdk/test/nvmf/host/multipath.sh (revision b30d57cdad6d2bc75cc1e4e2ebbcebcb0d98dcfa)
1#!/usr/bin/env bash
2
3testdir=$(readlink -f $(dirname $0))
4rootdir=$(readlink -f $testdir/../../..)
5source $rootdir/test/common/autotest_common.sh
6source $rootdir/test/nvmf/common.sh
7
8MALLOC_BDEV_SIZE=64
9MALLOC_BLOCK_SIZE=512
10
11rpc_py="$rootdir/scripts/rpc.py"
12
13bdevperf_rpc_sock=/var/tmp/bdevperf.sock
14
15nvmftestinit
16
17# This issue brings up a weird error in soft roce where the RDMA WC doesn't point to the correct qpair.
18if check_ip_is_soft_roce $NVMF_FIRST_TARGET_IP && [ "$TEST_TRANSPORT" == "rdma" ]; then
19	echo "Using software RDMA, not running this test due to a known issue."
20	exit 0
21fi
22
23nvmfappstart -m 0xF
24
25$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
26$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
27$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
28$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
29$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
30$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT
31$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT
32
33$rootdir/test/bdev/bdevperf/bdevperf -z -r $bdevperf_rpc_sock -q 128 -o 4096 -w verify -t 10 -f &> $testdir/try.txt &
34bdevperf_pid=$!
35
36trap 'process_shm --id $NVMF_APP_SHM_ID; rm -f $testdir/try.txt; killprocess $bdevperf_pid; nvmftestfini; exit 1' SIGINT SIGTERM EXIT
37waitforlisten $bdevperf_pid $bdevperf_rpc_sock
38$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
39$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
40
41$rootdir/test/bdev/bdevperf/bdevperf.py -s $bdevperf_rpc_sock perform_tests &
42rpc_pid=$!
43
44sleep 1
45
46$rpc_py nvmf_subsystem_remove_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
47
48sleep 3
49
50$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
51$rpc_py nvmf_subsystem_remove_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT
52
53sleep 3
54
55# Give the admin qpair time to fail before we add the new listener in. This prevents us from trying to connect to the wrong trid.
56$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
57
58sleep 1
59
60$rpc_py nvmf_subsystem_remove_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT
61
62wait $rpc_pid
63
64killprocess $bdevperf_pid
65
66cat $testdir/try.txt
67# if this test fails it means we didn't fail over to the second
68count="$(grep -c "Resetting controller successful" < $testdir/try.txt)"
69
70if ((count != 3)); then
71	false
72fi
73
74# Part 2 of the test. Start removing ports, starting with the one we are connected to, confirm that the ctrlr remains active until the final trid is removed.
75$rootdir/test/bdev/bdevperf/bdevperf -z -r $bdevperf_rpc_sock -q 128 -o 4096 -w verify -t 1 -f &> $testdir/try.txt &
76bdevperf_pid=$!
77
78waitforlisten $bdevperf_pid $bdevperf_rpc_sock
79$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT
80$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT
81$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
82$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
83$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
84
85$rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0
86
87$rpc_py -s $bdevperf_rpc_sock bdev_nvme_detach_controller NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
88
89# Async operation since we need to reconnect with new TRID.
90sleep 3
91$rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0
92$rootdir/test/bdev/bdevperf/bdevperf.py -s $bdevperf_rpc_sock perform_tests &
93rpc_pid=$!
94
95wait $rpc_pid
96
97# No need to wait here since we are deleting a TRID we aren't connected to.
98$rpc_py -s $bdevperf_rpc_sock bdev_nvme_detach_controller NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
99$rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0
100$rpc_py -s $bdevperf_rpc_sock bdev_nvme_detach_controller NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
101sleep 3
102
103if $rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0; then
104	echo "Controller was not properly removed."
105	false
106fi
107
108killprocess $bdevperf_pid
109
110sync
111$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode1
112
113trap - SIGINT SIGTERM EXIT
114
115rm -f $testdir/try.txt
116nvmftestfini