1.. SPDX-License-Identifier: BSD-3-Clause 2 Copyright(c) 2010-2014 Intel Corporation. 3 4VM Power Management Application 5=============================== 6 7Introduction 8------------ 9 10Applications running in Virtual Environments have an abstract view of 11the underlying hardware on the Host, in particular applications cannot see 12the binding of virtual to physical hardware. 13When looking at CPU resourcing, the pinning of Virtual CPUs(vCPUs) to 14Host Physical CPUs(pCPUS) is not apparent to an application 15and this pinning may change over time. 16Furthermore, Operating Systems on virtual machines do not have the ability 17to govern their own power policy; the Machine Specific Registers (MSRs) 18for enabling P-State transitions are not exposed to Operating Systems 19running on Virtual Machines(VMs). 20 21The Virtual Machine Power Management solution shows an example of 22how a DPDK application can indicate its processing requirements using VM local 23only information(vCPU/lcore, etc.) to a Host based Monitor which is responsible 24for accepting requests for frequency changes for a vCPU, translating the vCPU 25to a pCPU via libvirt and affecting the change in frequency. 26 27The solution is comprised of two high-level components: 28 29#. Example Host Application 30 31 Using a Command Line Interface(CLI) for VM->Host communication channel management 32 allows adding channels to the Monitor, setting and querying the vCPU to pCPU pinning, 33 inspecting and manually changing the frequency for each CPU. 34 The CLI runs on a single lcore while the thread responsible for managing 35 VM requests runs on a second lcore. 36 37 VM requests arriving on a channel for frequency changes are passed 38 to the librte_power ACPI cpufreq sysfs based library. 39 The Host Application relies on both qemu-kvm and libvirt to function. 40 41 This monitoring application is responsible for: 42 43 - Accepting requests from client applications: Client applications can 44 request frequency changes for a vCPU, translating 45 the vCPU to a pCPU via libvirt and affecting the change in frequency. 46 47 - Accepting policies from client applications: Client application can 48 send a policy to the host application. The 49 host application will then apply the rules of the policy independent 50 of the application. For example, the policy can contain time-of-day 51 information for busy/quiet periods, and the host application can scale 52 up/down the relevant cores when required. See the details of the guest 53 application below for more information on setting the policy values. 54 55 - Out-of-band monitoring of workloads via cores hardware event counters: 56 The host application can manage power for an application in a virtualised 57 OR non-virtualised environment by looking at the event counters of the 58 cores and taking action based on the branch hit/miss ratio. See the host 59 application '--core-list' command line parameter below. 60 61#. librte_power for Virtual Machines 62 63 Using an alternate implementation for the librte_power API, requests for 64 frequency changes are forwarded to the host monitor rather than 65 the APCI cpufreq sysfs interface used on the host. 66 67 The l3fwd-power application will use this implementation when deployed on a VM 68 (see :doc:`l3_forward_power_man`). 69 70.. _figure_vm_power_mgr_highlevel: 71 72.. figure:: img/vm_power_mgr_highlevel.* 73 74 Highlevel Solution 75 76 77Overview 78-------- 79 80VM Power Management employs qemu-kvm to provide communications channels 81between the host and VMs in the form of Virtio-Serial which appears as 82a paravirtualized serial device on a VM and can be configured to use 83various backends on the host. For this example each Virtio-Serial endpoint 84on the host is configured as AF_UNIX file socket, supporting poll/select 85and epoll for event notification. 86In this example each channel endpoint on the host is monitored via 87epoll for EPOLLIN events. 88Each channel is specified as qemu-kvm arguments or as libvirt XML for each VM, 89where each VM can have a number of channels up to a maximum of 64 per VM, 90in this example each DPDK lcore on a VM has exclusive access to a channel. 91 92To enable frequency changes from within a VM, a request via the librte_power interface 93is forwarded via Virtio-Serial to the host, each request contains the vCPU 94and power command(scale up/down/min/max). 95The API for host and guest librte_power is consistent across environments, 96with the selection of VM or Host Implementation determined at automatically 97at runtime based on the environment. 98 99Upon receiving a request, the host translates the vCPU to a pCPU via 100the libvirt API before forwarding to the host librte_power. 101 102.. _figure_vm_power_mgr_vm_request_seq: 103 104.. figure:: img/vm_power_mgr_vm_request_seq.* 105 106 VM request to scale frequency 107 108 109Performance Considerations 110~~~~~~~~~~~~~~~~~~~~~~~~~~ 111 112While Haswell Microarchitecture allows for independent power control for each core, 113earlier Microarchtectures do not offer such fine grained control. 114When deployed on pre-Haswell platforms greater care must be taken in selecting 115which cores are assigned to a VM, for instance a core will not scale down 116until its sibling is similarly scaled. 117 118Configuration 119------------- 120 121BIOS 122~~~~ 123 124Enhanced Intel SpeedStep® Technology must be enabled in the platform BIOS 125if the power management feature of DPDK is to be used. 126Otherwise, the sys file folder /sys/devices/system/cpu/cpu0/cpufreq will not exist, 127and the CPU frequency-based power management cannot be used. 128Consult the relevant BIOS documentation to determine how these settings 129can be accessed. 130 131Host Operating System 132~~~~~~~~~~~~~~~~~~~~~ 133 134The DPDK Power Library can use either the *acpi_cpufreq* or *intel_pstate* 135kernel driver for the management of core frequencies. In many cases 136the *intel_pstate* driver is the default Power Management environment. 137 138Should the *acpi-cpufreq* driver be required, the *intel_pstate* module must 139be disabled, and *apci_cpufreq* module loaded in its place. 140 141To disable *intel_pstate* driver, add the following to the grub Linux 142command line: 143 144.. code-block:: console 145 146 intel_pstate=disable 147 148Upon rebooting, load the *acpi_cpufreq* module: 149 150.. code-block:: console 151 152 modprobe acpi_cpufreq 153 154Hypervisor Channel Configuration 155~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 156 157Virtio-Serial channels are configured via libvirt XML: 158 159 160.. code-block:: xml 161 162 <name>{vm_name}</name> 163 <controller type='virtio-serial' index='0'> 164 <address type='pci' domain='0x0000' bus='0x00' slot='0x06' function='0x0'/> 165 </controller> 166 <channel type='unix'> 167 <source mode='bind' path='/tmp/powermonitor/{vm_name}.{channel_num}'/> 168 <target type='virtio' name='virtio.serial.port.poweragent.{vm_channel_num}'/> 169 <address type='virtio-serial' controller='0' bus='0' port='{N}'/> 170 </channel> 171 172 173Where a single controller of type *virtio-serial* is created and up to 32 channels 174can be associated with a single controller and multiple controllers can be specified. 175The convention is to use the name of the VM in the host path *{vm_name}* and 176to increment *{channel_num}* for each channel, likewise the port value *{N}* 177must be incremented for each channel. 178 179Each channel on the host will appear in *path*, the directory */tmp/powermonitor/* 180must first be created and given qemu permissions 181 182.. code-block:: console 183 184 mkdir /tmp/powermonitor/ 185 chown qemu:qemu /tmp/powermonitor 186 187Note that files and directories within /tmp are generally removed upon 188rebooting the host and the above steps may need to be carried out after each reboot. 189 190The serial device as it appears on a VM is configured with the *target* element attribute *name* 191and must be in the form of *virtio.serial.port.poweragent.{vm_channel_num}*, 192where *vm_channel_num* is typically the lcore channel to be used in DPDK VM applications. 193 194Each channel on a VM will be present at */dev/virtio-ports/virtio.serial.port.poweragent.{vm_channel_num}* 195 196Compiling and Running the Host Application 197------------------------------------------ 198 199Compiling 200~~~~~~~~~ 201 202For information on compiling DPDK and the sample applications 203see :doc:`compiling`. 204 205The application is located in the ``vm_power_manager`` sub-directory. 206 207To build just the ``vm_power_manager`` application using ``make``: 208 209.. code-block:: console 210 211 export RTE_SDK=/path/to/rte_sdk 212 export RTE_TARGET=build 213 cd ${RTE_SDK}/examples/vm_power_manager/ 214 make 215 216The resulting binary will be ${RTE_SDK}/build/examples/vm_power_manager 217 218To build just the ``vm_power_manager`` application using ``meson/ninja``: 219 220.. code-block:: console 221 222 export RTE_SDK=/path/to/rte_sdk 223 cd ${RTE_SDK} 224 meson build 225 cd build 226 ninja 227 meson configure -Dexamples=vm_power_manager 228 ninja 229 230The resulting binary will be ${RTE_SDK}/build/examples/dpdk-vm_power_manager 231 232Running 233~~~~~~~ 234 235The application does not have any specific command line options other than *EAL*: 236 237.. code-block:: console 238 239 ./build/vm_power_mgr [EAL options] 240 241The application requires exactly two cores to run, one core is dedicated to the CLI, 242while the other is dedicated to the channel endpoint monitor, for example to run 243on cores 0 & 1 on a system with 4 memory channels: 244 245.. code-block:: console 246 247 ./build/vm_power_mgr -l 0-1 -n 4 248 249After successful initialization the user is presented with VM Power Manager CLI: 250 251.. code-block:: console 252 253 vm_power> 254 255Virtual Machines can now be added to the VM Power Manager: 256 257.. code-block:: console 258 259 vm_power> add_vm {vm_name} 260 261When a {vm_name} is specified with the *add_vm* command a lookup is performed 262with libvirt to ensure that the VM exists, {vm_name} is used as an unique identifier 263to associate channels with a particular VM and for executing operations on a VM within the CLI. 264VMs do not have to be running in order to add them. 265 266A number of commands can be issued via the CLI in relation to VMs: 267 268 Remove a Virtual Machine identified by {vm_name} from the VM Power Manager. 269 270 .. code-block:: console 271 272 rm_vm {vm_name} 273 274 Add communication channels for the specified VM, the virtio channels must be enabled 275 in the VM configuration(qemu/libvirt) and the associated VM must be active. 276 {list} is a comma-separated list of channel numbers to add, using the keyword 'all' 277 will attempt to add all channels for the VM: 278 279 .. code-block:: console 280 281 add_channels {vm_name} {list}|all 282 283 Enable or disable the communication channels in {list}(comma-separated) 284 for the specified VM, alternatively list can be replaced with keyword 'all'. 285 Disabled channels will still receive packets on the host, however the commands 286 they specify will be ignored. Set status to 'enabled' to begin processing requests again: 287 288 .. code-block:: console 289 290 set_channel_status {vm_name} {list}|all enabled|disabled 291 292 Print to the CLI the information on the specified VM, the information 293 lists the number of vCPUS, the pinning to pCPU(s) as a bit mask, along with 294 any communication channels associated with each VM, along with the status of each channel: 295 296 .. code-block:: console 297 298 show_vm {vm_name} 299 300 Set the binding of Virtual CPU on VM with name {vm_name} to the Physical CPU mask: 301 302 .. code-block:: console 303 304 set_pcpu_mask {vm_name} {vcpu} {pcpu} 305 306 Set the binding of Virtual CPU on VM to the Physical CPU: 307 308 .. code-block:: console 309 310 set_pcpu {vm_name} {vcpu} {pcpu} 311 312Manual control and inspection can also be carried in relation CPU frequency scaling: 313 314 Get the current frequency for each core specified in the mask: 315 316 .. code-block:: console 317 318 show_cpu_freq_mask {mask} 319 320 Set the current frequency for the cores specified in {core_mask} by scaling each up/down/min/max: 321 322 .. code-block:: console 323 324 set_cpu_freq {core_mask} up|down|min|max 325 326 Get the current frequency for the specified core: 327 328 .. code-block:: console 329 330 show_cpu_freq {core_num} 331 332 Set the current frequency for the specified core by scaling up/down/min/max: 333 334 .. code-block:: console 335 336 set_cpu_freq {core_num} up|down|min|max 337 338There are also some command line parameters for enabling the out-of-band 339monitoring of branch ratio on cores doing busy polling via PMDs. 340 341 .. code-block:: console 342 343 --core-list {list of cores} 344 345 When this parameter is used, the list of cores specified will monitor the ratio 346 between branch hits and branch misses. A tightly polling PMD thread will have a 347 very low branch ratio, so the core frequency will be scaled down to the minimum 348 allowed value. When packets are received, the code path will alter, causing the 349 branch ratio to increase. When the ratio goes above the ratio threshold, the 350 core frequency will be scaled up to the maximum allowed value. 351 352 .. code-block:: console 353 354 --branch-ratio {ratio} 355 356 The branch ratio is a floating point number that specifies the threshold at which 357 to scale up or down for the given workload. The default branch ratio is 0.01, 358 and will need to be adjusted for different workloads. 359 360 361 362JSON API 363~~~~~~~~ 364 365In addition to the command line interface for host command and a virtio-serial 366interface for VM power policies, there is also a JSON interface through which 367power commands and policies can be sent. This functionality adds a dependency 368on the Jansson library, and the Jansson development package must be installed 369on the system before the JSON parsing functionality is included in the app. 370This is achieved by: 371 372 .. code-block:: javascript 373 374 apt-get install libjansson-dev 375 376The command and package name may be different depending on your operating 377system. It's worth noting that the app will successfully build without this 378package present, but a warning is shown during compilation, and the JSON 379parsing functionality will not be present in the app. 380 381Sending a command or policy to the power manager application is achieved by 382simply opening a fifo file, writing a JSON string to that fifo, and closing 383the file. 384 385The fifo is at /tmp/powermonitor/fifo 386 387The JSON string can be a policy or instruction, and takes the following 388format: 389 390 .. code-block:: javascript 391 392 {"packet_type": { 393 "pair_1": value, 394 "pair_2": value 395 }} 396 397The 'packet_type' header can contain one of two values, depending on 398whether a policy or power command is being sent. The two possible values are 399"policy" and "instruction", and the expected name-value pairs is different 400depending on which type is being sent. 401 402The pairs are the format of standard JSON name-value pairs. The value type 403varies between the different name/value pairs, and may be integers, strings, 404arrays, etc. Examples of policies follow later in this document. The allowed 405names and value types are as follows: 406 407 408:Pair Name: "name" 409:Description: Name of the VM or Host. Allows the parser to associate the 410 policy with the relevant VM or Host OS. 411:Type: string 412:Values: any valid string 413:Required: yes 414:Example: 415 416 .. code-block:: javascript 417 418 "name", "ubuntu2" 419 420 421:Pair Name: "command" 422:Description: The type of packet we're sending to the power manager. We can be 423 creating or destroying a policy, or sending a direct command to adjust 424 the frequency of a core, similar to the command line interface. 425:Type: string 426:Values: 427 428 :CREATE: used when creating a new policy, 429 :DESTROY: used when removing a policy, 430 :POWER: used when sending an immediate command, max, min, etc. 431:Required: yes 432:Example: 433 434 .. code-block:: javascript 435 436 "command", "CREATE" 437 438 439:Pair Name: "policy_type" 440:Description: Type of policy to apply. Please see vm_power_manager documentation 441 for more information on the types of policies that may be used. 442:Type: string 443:Values: 444 445 :TIME: Time-of-day policy. Frequencies of the relevant cores are 446 scaled up/down depending on busy and quiet hours. 447 :TRAFFIC: This policy takes statistics from the NIC and scales up 448 and down accordingly. 449 :WORKLOAD: This policy looks at how heavily loaded the cores are, 450 and scales up and down accordingly. 451 :BRANCH_RATIO: This out-of-band policy can look at the ratio between 452 branch hits and misses on a core, and is useful for detecting 453 how much packet processing a core is doing. 454:Required: only for CREATE/DESTROY command 455:Example: 456 457 .. code-block:: javascript 458 459 "policy_type", "TIME" 460 461:Pair Name: "busy_hours" 462:Description: The hours of the day in which we scale up the cores for busy 463 times. 464:Type: array of integers 465:Values: array with list of hour numbers, (0-23) 466:Required: only for TIME policy 467:Example: 468 469 .. code-block:: javascript 470 471 "busy_hours":[ 17, 18, 19, 20, 21, 22, 23 ] 472 473:Pair Name: "quiet_hours" 474:Description: The hours of the day in which we scale down the cores for quiet 475 times. 476:Type: array of integers 477:Values: array with list of hour numbers, (0-23) 478:Required: only for TIME policy 479:Example: 480 481 .. code-block:: javascript 482 483 "quiet_hours":[ 2, 3, 4, 5, 6 ] 484 485:Pair Name: "avg_packet_thresh" 486:Description: Threshold below which the frequency will be set to min for 487 the TRAFFIC policy. If the traffic rate is above this and below max, the 488 frequency will be set to medium. 489:Type: integer 490:Values: The number of packets below which the TRAFFIC policy applies the 491 minimum frequency, or medium frequency if between avg and max thresholds. 492:Required: only for TRAFFIC policy 493:Example: 494 495 .. code-block:: javascript 496 497 "avg_packet_thresh": 100000 498 499:Pair Name: "max_packet_thresh" 500:Description: Threshold above which the frequency will be set to max for 501 the TRAFFIC policy 502:Type: integer 503:Values: The number of packets per interval above which the TRAFFIC policy 504 applies the maximum frequency 505:Required: only for TRAFFIC policy 506:Example: 507 508 .. code-block:: javascript 509 510 "max_packet_thresh": 500000 511 512:Pair Name: "core_list" 513:Description: The cores to which to apply the policy. 514:Type: array of integers 515:Values: array with list of virtual CPUs. 516:Required: only policy CREATE/DESTROY 517:Example: 518 519 .. code-block:: javascript 520 521 "core_list":[ 10, 11 ] 522 523:Pair Name: "workload" 524:Description: When our policy is of type WORKLOAD, we need to specify how 525 heavy our workload is. 526:Type: string 527:Values: 528 529 :HIGH: For cores running workloads that require high frequencies 530 :MEDIUM: For cores running workloads that require medium frequencies 531 :LOW: For cores running workloads that require low frequencies 532:Required: only for WORKLOAD policy types 533:Example: 534 535 .. code-block:: javascript 536 537 "workload", "MEDIUM" 538 539:Pair Name: "mac_list" 540:Description: When our policy is of type TRAFFIC, we need to specify the 541 MAC addresses that the host needs to monitor 542:Type: string 543:Values: array with a list of mac address strings. 544:Required: only for TRAFFIC policy types 545:Example: 546 547 .. code-block:: javascript 548 549 "mac_list":[ "de:ad:be:ef:01:01", "de:ad:be:ef:01:02" ] 550 551:Pair Name: "unit" 552:Description: the type of power operation to apply in the command 553:Type: string 554:Values: 555 556 :SCALE_MAX: Scale frequency of this core to maximum 557 :SCALE_MIN: Scale frequency of this core to minimum 558 :SCALE_UP: Scale up frequency of this core 559 :SCALE_DOWN: Scale down frequency of this core 560 :ENABLE_TURBO: Enable Turbo Boost for this core 561 :DISABLE_TURBO: Disable Turbo Boost for this core 562:Required: only for POWER instruction 563:Example: 564 565 .. code-block:: javascript 566 567 "unit", "SCALE_MAX" 568 569:Pair Name: "resource_id" 570:Description: The core to which to apply the power command. 571:Type: integer 572:Values: valid core id for VM or host OS. 573:Required: only POWER instruction 574:Example: 575 576 .. code-block:: javascript 577 578 "resource_id": 10 579 580JSON API Examples 581~~~~~~~~~~~~~~~~~ 582 583Profile create example: 584 585 .. code-block:: javascript 586 587 {"policy": { 588 "name": "ubuntu", 589 "command": "create", 590 "policy_type": "TIME", 591 "busy_hours":[ 17, 18, 19, 20, 21, 22, 23 ], 592 "quiet_hours":[ 2, 3, 4, 5, 6 ], 593 "core_list":[ 11 ] 594 }} 595 596Profile destroy example: 597 598 .. code-block:: javascript 599 600 {"policy": { 601 "name": "ubuntu", 602 "command": "destroy", 603 }} 604 605Power command example: 606 607 .. code-block:: javascript 608 609 {"instruction": { 610 "name": "ubuntu", 611 "command": "power", 612 "unit": "SCALE_MAX", 613 "resource_id": 10 614 }} 615 616To send a JSON string to the Power Manager application, simply paste the 617example JSON string into a text file and cat it into the fifo: 618 619 .. code-block:: console 620 621 cat file.json >/tmp/powermonitor/fifo 622 623The console of the Power Manager application should indicate the command that 624was just received via the fifo. 625 626Compiling and Running the Guest Applications 627-------------------------------------------- 628 629l3fwd-power is one sample application that can be used with vm_power_manager. 630 631A guest CLI is also provided for validating the setup. 632 633For both l3fwd-power and guest CLI, the channels for the VM must be monitored by the 634host application using the *add_channels* command on the host. This typically uses 635the following commands in the host application: 636 637.. code-block:: console 638 639 vm_power> add_vm vmname 640 vm_power> add_channels vmname all 641 vm_power> set_channel_status vmname all enabled 642 vm_power> show_vm vmname 643 644 645Compiling 646~~~~~~~~~ 647 648For information on compiling DPDK and the sample applications 649see :doc:`compiling`. 650 651For compiling and running l3fwd-power, see :doc:`l3_forward_power_man`. 652 653The application is located in the ``guest_cli`` sub-directory under ``vm_power_manager``. 654 655To build just the ``guest_vm_power_manager`` application using ``make``: 656 657.. code-block:: console 658 659 export RTE_SDK=/path/to/rte_sdk 660 export RTE_TARGET=build 661 cd ${RTE_SDK}/examples/vm_power_manager/guest_cli/ 662 make 663 664The resulting binary will be ${RTE_SDK}/build/examples/guest_cli 665 666.. Note:: 667 This sample application conditionally links in the Jansson JSON 668 library, so if you are using a multilib or cross compile environment you 669 may need to set the ``PKG_CONFIG_LIBDIR`` environmental variable to point to 670 the relevant pkgconfig folder so that the correct library is linked in. 671 672 For example, if you are building for a 32-bit target, you could find the 673 correct directory using the following ``find`` command: 674 675 .. code-block:: console 676 677 # find /usr -type d -name pkgconfig 678 /usr/lib/i386-linux-gnu/pkgconfig 679 /usr/lib/x86_64-linux-gnu/pkgconfig 680 681 Then use: 682 683 .. code-block:: console 684 685 export PKG_CONFIG_LIBDIR=/usr/lib/i386-linux-gnu/pkgconfig 686 687 You then use the make command as normal, which should find the 32-bit 688 version of the library, if it installed. If not, the application will 689 be built without the JSON interface functionality. 690 691To build just the ``vm_power_manager`` application using ``meson/ninja``: 692 693.. code-block:: console 694 695 export RTE_SDK=/path/to/rte_sdk 696 cd ${RTE_SDK} 697 meson build 698 cd build 699 ninja 700 meson configure -Dexamples=vm_power_manager/guest_cli 701 ninja 702 703The resulting binary will be ${RTE_SDK}/build/examples/guest_cli 704 705Running 706~~~~~~~ 707 708The standard *EAL* command line parameters are required: 709 710.. code-block:: console 711 712 ./build/guest_vm_power_mgr [EAL options] -- [guest options] 713 714The guest example uses a channel for each lcore enabled. For example, 715to run on cores 0,1,2,3: 716 717.. code-block:: console 718 719 ./build/guest_vm_power_mgr -l 0-3 720 721Optionally, there is a list of command line parameter should the user wish to send a power 722policy down to the host application. These parameters are as follows: 723 724 .. code-block:: console 725 726 --vm-name {name of guest vm} 727 728 This parameter allows the user to change the Virtual Machine name passed down to the 729 host application via the power policy. The default is "ubuntu2" 730 731 .. code-block:: console 732 733 --vcpu-list {list vm cores} 734 735 A comma-separated list of cores in the VM that the user wants the host application to 736 monitor. The list of cores in any vm starts at zero, and these are mapped to the 737 physical cores by the host application once the policy is passed down. 738 Valid syntax includes individual cores '2,3,4', or a range of cores '2-4', or a 739 combination of both '1,3,5-7' 740 741 .. code-block:: console 742 743 --busy-hours {list of busy hours} 744 745 A comma-separated list of hours within which to set the core frequency to maximum. 746 Valid syntax includes individual hours '2,3,4', or a range of hours '2-4', or a 747 combination of both '1,3,5-7'. Valid hours are 0 to 23. 748 749 .. code-block:: console 750 751 --quiet-hours {list of quiet hours} 752 753 A comma-separated list of hours within which to set the core frequency to minimum. 754 Valid syntax includes individual hours '2,3,4', or a range of hours '2-4', or a 755 combination of both '1,3,5-7'. Valid hours are 0 to 23. 756 757 .. code-block:: console 758 759 --policy {policy type} 760 761 The type of policy. This can be one of the following values: 762 TRAFFIC - based on incoming traffic rates on the NIC. 763 TIME - busy/quiet hours policy. 764 BRANCH_RATIO - uses branch ratio counters to determine core busyness. 765 Not all parameters are needed for all policy types. For example, BRANCH_RATIO 766 only needs the vcpu-list parameter, not any of the hours. 767 768 769After successful initialization the user is presented with VM Power Manager Guest CLI: 770 771.. code-block:: console 772 773 vm_power(guest)> 774 775To change the frequency of a lcore, use the set_cpu_freq command. 776Where {core_num} is the lcore and channel to change frequency by scaling up/down/min/max. 777 778.. code-block:: console 779 780 set_cpu_freq {core_num} up|down|min|max 781 782To start the application and configure the power policy, and send it to the host: 783 784.. code-block:: console 785 786 ./build/guest_vm_power_mgr -l 0-3 -n 4 -- --vm-name=ubuntu --policy=BRANCH_RATIO --vcpu-list=2-4 787 788Once the VM Power Manager Guest CLI appears, issuing the 'send_policy now' command 789will send the policy to the host: 790 791.. code-block:: console 792 793 send_policy now 794 795Once the policy is sent to the host, the host application takes over the power monitoring 796of the specified cores in the policy. 797 798