xref: /netbsd-src/sys/dev/i2c/hytp14var.h (revision d1f20b9e2f146af1de45bb1a0e4507aea6604f09)
1 /* $NetBSD: hytp14var.h,v 1.4 2016/07/03 12:26:55 kardel Exp $ */
2 
3 /*-
4  * Copyright (c) 2014,2016 The NetBSD Foundation, Inc.
5  * All rights reserved.
6  *
7  * This code is derived from software contributed to The NetBSD Foundation
8  * by Frank Kardel.
9  *
10  * Redistribution and use in source and binary forms, with or without
11  * modification, are permitted provided that the following conditions
12  * are met:
13  * 1. Redistributions of source code must retain the above copyright
14  *    notice, this list of conditions and the following disclaimer.
15  * 2. Redistributions in binary form must reproduce the above copyright
16  *    notice, this list of conditions and the following disclaimer in the
17  *    documentation and/or other materials provided with the distribution.
18  *
19  * THIS SOFTWARE IS PROVIDED BY THE NETBSD FOUNDATION, INC. AND CONTRIBUTORS
20  * ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED
21  * TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
22  * PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE FOUNDATION OR CONTRIBUTORS
23  * BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
24  * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
25  * SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
26  * INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
27  * CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
28  * ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
29  * POSSIBILITY OF SUCH DAMAGE.
30  */
31 
32 /*
33  * IST-AG P14 calibrated Hygro-/Temperature sensor module
34  * Devices: HYT-271, HYT-221 and HYT-939
35  *
36  * see:
37  * http://www.ist-ag.com/eh/ist-ag/resource.nsf/imgref/Download_AHHYTM_E2.1.pdf/
38  *      $FILE/AHHYTM_E2.1.pdf
39  */
40 #ifndef _DEV_I2C_HYTP14VAR_H_
41 #define _DEV_I2C_HYTP14VAR_H_
42 
43 #define HYTP14_DEFAULT_ADDR	0x28
44 
45 #define HYTP14_NUM_SENSORS	2
46 
47 /* the default measurement interval is 50 seconds */
48 #define HYTP14_MR_INTERVAL	50
49 
50 #define HYTP14_THR_INIT		0
51 #define HYTP14_THR_RUN		1
52 #define HYTP14_THR_STOP		2
53 
54 struct hytp14_sc {
55 	device_t	sc_dev;
56 	i2c_tag_t	sc_tag;
57 	i2c_addr_t	sc_addr;
58 
59 	kmutex_t	sc_mutex;
60 	kcondvar_t	sc_condvar;
61 	struct lwp     *sc_thread;  /* measurement poll thread */
62 	int		sc_state;   /* thread communication */
63 
64 	int		sc_valid;   /* ENVSYS validity state for this sensor */
65 	uint8_t		sc_data[4]; /* current sensor data */
66 	uint8_t		sc_last[4]; /* last sensor data, before MR */
67 
68 	int		sc_numsensors;
69 
70 	int32_t		sc_mrinterval;
71 
72 	struct sysmon_envsys *sc_sme;
73 	envsys_data_t sc_sensors[HYTP14_NUM_SENSORS];
74 };
75 
76 struct hytp14_sensor {
77 	const char	  *desc;
78 	enum envsys_units  type;
79 	void		 (*refresh)(struct hytp14_sc *, envsys_data_t *);
80 };
81 
82 #endif