Lines Matching full:input

48 utility copies the standard input to the standard output, applying any
50 Input data is read and written in 512-byte blocks.
51 If input reads are short, input from multiple reads are aggregated
55 displays the number of complete and partial input and output blocks
56 and truncated input records to the standard error output.
61 Read input from
63 instead of the standard input.
76 Set the input block size to
84 Set both the input and output block size to
96 are specified, then each input block is copied to the output as a
107 input blocks.
111 input files before terminating.
112 This operand is only applicable when the input device is a tape.
130 blocks from the beginning of the input before copying.
131 On input which supports seeks, an
134 Otherwise, input data is read and discarded.
165 Treats the input as a sequence of newline or end-of-file terminated variable
166 length records independent of input and output block boundaries.
168 Each input record is converted to a fixed length output record where the
172 Input records shorter than the conversion record size are padded with spaces.
173 Input records longer than the conversion record size are truncated.
174 The number of truncated input records, if any, is reported to the standard
204 Do not stop processing on an input error.
205 When an input error occurs, a diagnostic message followed by the current
206 input and output block counts will be written to the standard error output
210 conversion is also specified, any missing input data will be replaced
212 specified) and processed as a normal input buffer.
215 conversion is not specified, the input block is omitted from the output.
216 On input files which are not tapes or pipes, the file offset
236 Swap every pair of input bytes.
237 If an input buffer has an odd number of bytes, the last byte will be
240 Pad every input block to the input buffer size.
246 Treats the input as a sequence of fixed length records independent of input
248 The length of the input records is specified by the
278 displays the number of complete and partial input and output blocks,
279 truncated input records, and odd-length byte-swapping blocks to the
281 A partial input block is one where less than the input block size
288 A truncated input block is one where a variable length record oriented
289 conversion value was specified and the input line was too long to
292 Normally, data resulting from input or conversion or both are aggregated
294 After the end of input is reached, any remaining output is written as
307 signal, the current input and output block counts will
314 signal, the current input and output block counts will