Lines Matching +full:cache +full:- +full:op +full:- +full:block +full:- +full:size
39 .Op Fl D Ar device
40 .Op Fl t Ar type
41 .Op Fl u Ar unit
44 .Op Fl D Ar device
45 .Op Fl t Ar type
46 .Op Fl u Ar unit
49 .Op Fl d
50 .Op Fl e
51 .Op Fl D Ar device
52 .Op Fl t Ar type
53 .Op Fl u Ar unit
56 .Op Fl D Ar device
57 .Op Fl t Ar type
58 .Op Fl u Ar unit
61 .Op Fl D Ar device
62 .Op Fl t Ar type
63 .Op Fl u Ar unit
65 .Op Fl c Ar class
66 .Op Fl l Ar locale
67 .Op Fl n Ar count
68 .Op Fl v
69 .Op Ar start Op Ar stop
71 .Op Fl D Ar device
72 .Op Fl t Ar type
73 .Op Fl u Ar unit
76 .Op Fl D Ar device
77 .Op Fl t Ar type
78 .Op Fl u Ar unit
79 .Cm show foreign Op Ar volume
81 .Op Fl D Ar device
82 .Op Fl t Ar type
83 .Op Fl u Ar unit
86 .Op Fl d
87 .Op Fl e
88 .Op Fl D Ar device
89 .Op Fl t Ar type
90 .Op Fl u Ar unit
93 .Op Fl d
94 .Op Fl e
95 .Op Fl D Ar device
96 .Op Fl t Ar type
97 .Op Fl u Ar unit
100 .Op Fl D Ar device
101 .Op Fl t Ar type
102 .Op Fl u Ar unit
105 .Op Fl D Ar device
106 .Op Fl t Ar type
107 .Op Fl u Ar unit
110 .Op Fl D Ar device
111 .Op Fl t Ar type
112 .Op Fl u Ar unit
115 .Op Fl D Ar device
116 .Op Fl t Ar type
117 .Op Fl u Ar unit
120 .Op Fl D Ar device
121 .Op Fl t Ar type
122 .Op Fl u Ar unit
125 .Op Fl D Ar device
126 .Op Fl t Ar type
127 .Op Fl u Ar unit
130 .Op Fl D Ar device
131 .Op Fl t Ar type
132 .Op Fl u Ar unit
135 .Op Fl D Ar device
136 .Op Fl t Ar type
137 .Op Fl u Ar unit
140 .Op Fl D Ar device
141 .Op Fl t Ar type
142 .Op Fl u Ar unit
145 .Op Fl D Ar device
146 .Op Fl t Ar type
147 .Op Fl u Ar unit
150 .Op Fl D Ar device
151 .Op Fl t Ar type
152 .Op Fl u Ar unit
153 .Cm cache Ar volume Op Ar setting Oo Ar value Oc Op ...
155 .Op Fl D Ar device
156 .Op Fl t Ar type
157 .Op Fl u Ar unit
160 .Op Fl D Ar device
161 .Op Fl t Ar type
162 .Op Fl u Ar unit
165 .Op Fl D Ar device
166 .Op Fl t Ar type
167 .Op Fl u Ar unit
170 .Op Fl D Ar device
171 .Op Fl t Ar type
172 .Op Fl u Ar unit
174 .Op Fl v
175 .Op Fl s Ar stripe_size
176 .Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
177 .Op Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
179 .Op Fl D Ar device
180 .Op Fl t Ar type
181 .Op Fl u Ar unit
184 .Op Fl D Ar device
185 .Op Fl t Ar type
186 .Op Fl u Ar unit
187 .Cm add Ar drive Op Ar volume
189 .Op Fl D Ar device
190 .Op Fl t Ar type
191 .Op Fl u Ar unit
194 .Op Fl D Ar device
195 .Op Fl t Ar type
196 .Op Fl u Ar unit
199 .Op Fl D Ar device
200 .Op Fl t Ar type
201 .Op Fl u Ar unit
204 .Op Fl D Ar device
205 .Op Fl t Ar type
206 .Op Fl u Ar unit
207 .Cm patrol Ar command Op Ar interval Op Ar start
209 .Op Fl D Ar device
210 .Op Fl t Ar type
211 .Op Fl u Ar unit
214 .Op Fl D Ar device
215 .Op Fl t Ar type
216 .Op Fl u Ar unit
217 .Cm foreign clear Op Ar config
219 .Op Fl D Ar device
220 .Op Fl t Ar type
221 .Op Fl u Ar unit
222 .Cm foreign diag Op Ar config
224 .Op Fl D Ar device
225 .Op Fl t Ar type
226 .Op Fl u Ar unit
227 .Cm foreign preview Op Ar config
229 .Op Fl D Ar device
230 .Op Fl t Ar type
231 .Op Fl u Ar unit
232 .Cm foreign import Op Ar config
234 .Op Fl D Ar device
235 .Op Fl t Ar type
236 .Op Fl u Ar unit
239 .Op Fl D Ar device
240 .Op Fl t Ar type
241 .Op Fl u Ar unit
244 .Op Fl D Ar device
245 .Op Fl t Ar type
246 .Op Fl u Ar unit
249 .Op Fl D Ar device
250 .Op Fl t Ar type
251 .Op Fl u Ar unit
252 .Cm ctrlprop Ar rebuild Op Ar rate
254 .Op Fl D Ar device
255 .Op Fl t Ar type
256 .Op Fl u Ar unit
257 .Cm ctrlprop Ar alarm Op Ar 0/1
270 .Bl -tag -width indent
294 .Bl -tag -width indent
315 .Op E Ar xx Ns \&:
347 The fifth group of commands are used to manage controller-wide operations.
350 .Bl -tag -width indent
366 .Op Fl c Ar class
367 .Op Fl l Ar locale
368 .Op Fl n Ar count
369 .Op Fl v
370 .Op Ar start Op Ar stop
382 .Bl -tag -width indent
386 Periodic progress updates for long-running operations such as background
421 the controller for each low-level request.
433 .Bl -tag -width indent
462 .Bl -tag -width indent
482 Present the drive to the host operating system as a disk SYSPD block device in
496 Abort an in-progress rebuild operation on
507 .Bl -tag -width indent
508 .It Cm cache Ar volume Op Ar setting Oo Ar value Oc Op ...
511 arguments are supplied, then the current cache policy for
515 the cache policy for
525 .Bl -tag -width indent
534 .It Cm write-back
535 Use write-back policy for cached writes.
536 .It Cm write-through
537 Use write-through policy for cached writes.
538 .It Cm read-ahead Ar value
547 .It Cm bad-bbu-write-cache Ar value
558 .It Cm write-cache Ar value
585 .Bl -tag -width indent
589 .Op Fl v
590 .Op Fl s Ar stripe_size
591 .Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
592 .Op Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
599 .Bl -tag -width indent
639 parameter allows the stripe size of the array to be set.
640 By default a stripe size of 64K is used.
646 .It Cm add Ar drive Op Ar volume
671 .Bl -tag -width indent
672 .It Cm patrol Ar command Op Ar interval Op Ar start
677 .Bl -tag -width indent
692 argument specifies a non-negative, relative start time for the next patrol read.
708 .It Cm foreign clear Op config
714 .It Cm foreign diag Op config
720 .It Cm foreign preview Op config
726 .It Cm foreign import Op config
740 In particular, the controller write cache will be disabled during the relearn
745 .Bl -tag -width indent
746 .It Cm learn-delay
749 .It Cm autolearn-mode
760 .It Cm bbu-mode
768 .It Cm ctrlprop Ar rebuild Op Ar rate
770 With an integer argument (0-100), set that value as the new rebuild rate for volumes.
771 .It Cm ctrlprop Ar alarm Op Ar 0/1
777 Configure the cache for volume mfid0 to cache only writes:
779 .Dl Nm Cm cache mfid0 writes
780 .Dl Nm Cm cache mfid0 write-back
803 Reconfigure a disk as a SYSPD block device with no RAID